Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Front Cardiovasc Med ; 11: 1369250, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38455723

RESUMO

Background: The use of SGLT-2 inhibitors has revolutionized heart failure therapy. Evidence suggests a reduced incidence of ventricular and atrial arrhythmias in patients with dapagliflozin or empagliflozin treatment. It is unclear to what extent the reduced arrhythmia burden is due to direct effects of the SGLT2 inhibitors or is solely a marker of improved cardiac function. Methods: One hundred five rabbit hearts were allocated to eight groups and retrogradely perfused, employing a Langendorff setup. Action potential duration at 90% of repolarization (APD90), QT intervals, effective refractory periods, conduction velocity, and dispersion of repolarization were obtained with monophasic action potential catheters. A model for tachyarrhythmias was established with the IKr blocker erythromycin for QT prolongation associated proarrhythmia as well as the potassium channel opener pinacidil for a short-QT model. An atrial fibrillation (AF) model was created with isoproterenol and acetylcholine. With increasing concentrations of both SGLT2 inhibitors, reductions in QT intervals and APD90 were observed, accompanied by a slight increase in ventricular arrhythmia episodes. During drug-induced proarrhythmia, empagliflozin succeeded in decreasing QT intervals, APD90, and VT burden whereas dapagliflozin demonstrated no significant effects. In the presence of pinacidil induced arrhythmogenicity, neither SGLT2 inhibitor had a significant impact on cardiac electrophysiology. In the AF setting, perfusion with dapagliflozin showed significant suppression of AF in the course of restitution of electrophysiological parameters whereas empagliflozin showed no significant effect on atrial fibrillation incidence. Conclusion: In this model, empagliflozin and dapagliflozin demonstrated opposite antiarrhythmic properties. Empagliflozin reduced ventricular tachyarrhythmias whereas dapagliflozin showed effective suppression of atrial arrhythmias.

2.
J Clin Med ; 13(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38541919

RESUMO

Sarcoidosis is a multisystem disorder of unknown etiology. The leading hypothesis involves an antigen-triggered dysregulated T-cell-driven immunologic response leading to non-necrotic granulomas. In cardiac sarcoidosis (CS), the inflammatory response can lead to fibrosis, culminating in clinical manifestations such as atrioventricular block and ventricular arrhythmias. Cardiac manifestations frequently present as first and isolated signs or may appear in conjunction with extracardiac manifestations. The incidence of sudden cardiac death (SCD) is high. Diagnosis remains a challenge. For a definite diagnosis, endomyocardial biopsy (EMB) is suggested. In clinical practice, compatible findings in advanced imaging using cardiovascular magnetic resonance (CMR) and/or positron emission tomography (PET) in combination with extracardiac histological proof is considered sufficient. Management revolves around the control of myocardial inflammation by employing immunosuppression. However, data regarding efficacy are merely based on observational evidence. Prevention of SCD is of particular importance and several guidelines provide recommendations regarding device therapy. In patients with manifest CS, outcome data indicate a 5-year survival of around 90% and a 10-year survival in the range of 80%. Data for patients with silent CS are conflicting; some studies suggest an overall benign course of disease while others reported contrasting observations. Future research challenges involve better understanding of the immunologic pathogenesis of the disease for a targeted therapy, improving imaging to aid early diagnosis, assessing the need for screening of asymptomatic patients and randomized trials.

3.
Heart Rhythm ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38382685

RESUMO

BACKGROUND: To assess the risk of unsuccessful conversion of ventricular fibrillation during defibrillation testing (DFT) with the subcutaneous implantable cardioverter-defibrillator (S-ICD), the PRAETORIAN score has been proposed. OBJECTIVE: The purpose of this study was to validate the PRAETORIAN score in a large S-ICD collective. METHODS: A retrospective single-center analysis of S-ICD patients receiving intraoperative DFT was performed. DFT was performed using a stepwise protocol with 65-J standard polarity, change of polarity, increase to 80 J, and repositioning if necessary. If all DFTs failed, we switched to a transvenous ICD. RESULTS: Overall, 398 patients were analyzed (268 male [67.3%]; mean age 42.4 ± 15.9 years; mean body mass index [BMI] 25.9 ± 4.8 kg/m2). Successful DFT with the first ICD shock was observed in 264 patients (66.3%). One hundred fourteen patients were defibrillated with the second (n = 104) or third (n = 10) DFT after changing shock polarity and/or shock energy. Overall, 20 patients needed at least 3 DFT (ie, 80 J and/or re-positioning). The majority (n = 88 [65.7%]) of DFT failures occurred before 2015 with the first-generation S-ICD. PRAETORIAN score was an independent predictor of DFT failure (odds ratio [OR] 1.007; 95% confidence interval [CI] 1.003-1.011 P ≤.001), while whereas BMI alone was not (P = .31). Presence of hypertrophic cardiomyopathy (HCM) (OR 2.6; 95% CI 1.3-4.4; P = .004) was predictive for at least 1 unsuccessful DFT in our multivariate regression analysis. CONCLUSION: PRAETORIAN score proved to be a useful and valid predictive tool for successful DFT, whereas BMI only had a limited role. Patients with HCM were at increased risk for DFT failure or needed higher DFT energy.

4.
Clin Res Cardiol ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353682

RESUMO

Despite impressive developments in the field of ventricular arrhythmias, there is still a relevant number of patients with ventricular arrhythmias who require antiarrhythmic drug therapy and may, e.g., in otherwise drug and/or ablation refractory situations, benefit from agents known for decades, such as mexiletine. Through its capability of blocking fast sodium channels in cardiomyocytes, it has played a minor to moderate antiarrhythmic role throughout the recent decades. Nevertheless, certain patients with structural heart disease suffering from drug-refractory, i.e., mainly amiodarone refractory ventricular arrhythmias, as well as those with selected forms of congenital long QT syndrome (LQTS) may nowadays still benefit from mexiletine. Here, we outline mexiletine's cellular and clinical electrophysiological properties. In addition, the application of mexiletine may be accompanied by various potential side effects, e.g., nausea and tremor, and is limited by several drug-drug interactions. Thus, we shed light on the current therapeutic role of mexiletine for therapy of ventricular arrhythmias and discuss clinically relevant aspects of its indications based on current evidence.

5.
Clin Res Cardiol ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38372753

RESUMO

BACKGROUND: Due to suspected pro-arrhythmic effects and increased mortality associated with class-IC antiarrhythmic drugs (AADs) in previous trials, AAD therapy in structural heart disease (SHD) is mainly restricted to amiodarone. In the presence of diagnostic and therapeutic advancements in cardiovascular medicine, it remains unclear if previous studies adequately reflect contemporary patients. In clinical practice, class-IC-AADs are occasionally used in individual cases, particularly in patients with an implantable cardioverter defibrillator (ICD). METHODS: This study retrospectively investigated outcome in ICD-carriers with SHD in whom class-IC-AADs were used as an individualized therapy due to failure, side effects, or unacceptable risk of alternative therapeutic options. RESULTS: Fifty patients from four tertiary centers were included (median age 48.5 years; 52% female). The most common underlying SHD were dilated (42%) or ischemic cardiomyopathy (26%) (median LVEF = 45%). Indications for AAD were sustained ventricular arrhythmias (VA) (58%), symptomatic premature ventricular contractions (26%), or atrial arrhythmias (16%). Median follow-up was 27.8 months. Freedom from sustained VA was 72%, and freedom from ICD therapy was 80%. In 19 patients (38%), AAD therapy was terminated. The most common reason was insufficient efficacy (n = 8). Pro-arrhythmia was suspected in three patients. Five patients died during follow-up (10.0%), two of cardiovascular cause (4.0%). CONCLUSION: In a multicenter cohort of ICD-carriers with SHD, class-IC-AADs were associated with a low rate of pro-arrhythmic effects or cardiovascular mortality. The majority of patients remained free from sustained VA during a follow-up of > 2 years. Further efforts should be made to evaluate the safety of class-IC-AADs in SHD patients receiving contemporary cardiovascular therapy.

6.
J Interv Card Electrophysiol ; 67(2): 253-255, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37715834

RESUMO

The aim of the present case series was to characterize the feasibility of a novel size adjustable cryoballoon system (PolarX Fit, Boston Scientific, Marlborough, MA, USA). This cryoballoon catheter can be inflated to two different diameters (28 mm and 31 mm) within the same procedure allowing vein adapted PVI. In summary, the novel size adjustable cryoballoon shows similar characteristics as the established versions. The intraprocedural flexibility of balloon size led to employment of the larger variant in the majority of freeze applications. Of note, in all but one procedure, both sizes were employed to ensure optimal occlusion for all veins. This initial series suggests that the size adjustable balloon offers more flexibility of obtain optimal occlusions in particular, in challenging anatomies, including common pulmonary vein ostia.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Estudos de Viabilidade , Veias Pulmonares/cirurgia , Cateteres , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-38043918

RESUMO

Atrial fibrillation (AF) is common in patients with chronic kidney disease (CKD) undergoing hemodialysis and in this patient population, management in terms of oral anticoagulation (OAC) presents unique challenges due to the increased risk of both thromboembolic events and bleeding complications. The attributable risk of AF for stroke may differ from patients without CKD, raising the question if OAC is indicated at all. Historically, vitamin K antagonists (VKA) have been the standard treatment for anticoagulation in AF; however, direct oral anticoagulants (DOACs) have emerged as an alternative therapeutic option, whereby data from prospective randomised trials with hemodialysis patients is limited resulting in great variability of practice and guideline recommendations. This review summarizes existing data sources regarding the use and benefit of oral anticoagulation with VKA and DOAC in hemodialysis patients.

9.
Clin Res Cardiol ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38112746

RESUMO

BACKGROUND: Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important. OBJECTIVE: To assess the performance of cryoablation procedural markers to predict long-term PVI. METHODS: In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse). RESULTS: 47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection. CONCLUSION: T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.

10.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38102318

RESUMO

AIMS: In-hospital complications of catheter ablation for atrial fibrillation (AF), atrial flutter (AFL), and ventricular tachycardia (VT) may be overestimated by analyses of administrative data. METHODS AND RESULTS: We determined the incidences of in-hospital mortality, major bleeding, and stroke around AF, AFL, and VT ablations in four German tertiary centres between 2005 and 2020. All cases were coded by the G-DRG- and OPS-systems. Uniform code search terms were applied defining both the types of ablations for AF, AFL, and VT and the occurrence of major adverse events including femoral vascular complications, iatrogenic tamponade, stroke, and in-hospital death. Importantly, all complications were individually reviewed based on patient-level source records. Overall, 43 031 ablations were analysed (30 361 AF; 9364 AFL; 3306 VT). The number of ablations/year more than doubled from 2005 (n = 1569) to 2020 (n = 3317) with 3 times and 2.5 times more AF and VT ablations in 2020 (n = 2404 and n = 301, respectively) as compared to 2005 (n = 817 and n = 120, respectively), but a rather stable number of AFL ablations (n = 554 vs. n = 612). Major peri-procedural complications occurred in 594 (1.4%) patients. Complication rates were 1.1% (n = 325) for AF, 1.0% (n = 95) for AFL, and 5.3% (n = 175) for VT. With an increase in complex AF/VT procedures, the overall complication rate significantly increased (0.76% in 2005 vs. 1.81% in 2020; P = 0.004); but remained low over time. Following patient-adjudication, all in-hospital cardiac tamponades (0.7%) and strokes (0.2%) were related to ablation. Major femoral vascular complications requiring surgical intervention occurred in 0.4% of all patients. The in-hospital mortality rate adjudicated to be ablation-related was lower than the coded mortality rate: AF: 0.03% vs. 0.04%; AFL: 0.04% vs. 0.14%; VT: 0.42% vs. 1.48%. CONCLUSION: Major adverse events are low and comparable after catheter ablation for AFL and AF (∼1.0%), whereas they are five times higher for VT ablations. In the presence of an increase in complex ablation procedures, a moderate but significant increase in overall complications from 2005-20 was observed. Individual case analysis demonstrated a lower than coded ablation-related in-hospital mortality. This highlights the importance of individual case adjudication when analysing administrative data.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Taquicardia Ventricular , Humanos , Mortalidade Hospitalar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/etiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Hospitais , Acidente Vascular Cerebral/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
11.
Clin Transl Sci ; 16(12): 2429-2437, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37781966

RESUMO

Lidocaine is classified as a class Ib anti-arrhythmic that blocks voltage- and pH-dependent sodium channels. It exhibits well investigated anti-arrhythmic effects and has been the anti-arrhythmic of choice for the treatment of ventricular arrhythmias for several decades. Lidocaine binds primarily to inactivated sodium channels, decreases the action potential duration, and increases the refractory period. It increases the ventricular fibrillatory threshold and can interrupt life-threatening tachycardias caused by re-entrant mechanisms, especially in ischemic tissue. Its use was pushed into the background in the era of amiodarone and modern electric device therapy. Recently, lidocaine has come back into focus for the treatment of acute sustained ventricular tachyarrhythmias. In this brief overview, we review the clinical pharmacology including possible side effects, the historical course, possible indications, and current Guideline recommendations for the use of lidocaine.


Assuntos
Amiodarona , Lidocaína , Humanos , Lidocaína/efeitos adversos , Antiarrítmicos/efeitos adversos , Amiodarona/efeitos adversos , Arritmias Cardíacas/tratamento farmacológico , Arritmias Cardíacas/induzido quimicamente , Canais de Sódio/uso terapêutico
12.
Clin Res Cardiol ; 112(12): 1778-1789, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37162594

RESUMO

OBJECTIVE AND BACKGROUND: Catheter-based treatment of patients with ventricular arrhythmias (VA) reduces VA and mortality in selected patients. With regard to potential risks of catheter ablation, a benefit-risk assessment should be carried out. This can be performed with risk scores such as the recently published "Risk in Ventricular Ablation (RIVA) Score". We sought to validate this score and to test for possible additional predictors in a large database of VT ablations. METHODS AND RESULTS: We analyzed 1964 catheter ablations for VA in patients with (1069; 54.4%) and without (893, 45.6%) structural heart disease (SHD) and observed an overall major adverse event rate of 4.0% with an in-hospital mortality of 1.3% with significantly less complications occurring in patients without structural heart disease (6.5% vs. 1.1%; p ≤ 0.01). The RIVA Score demonstrated to be a valid predictive tool for major in-hospital complications (OR 1.18; 95% CI 1.12, 1.25; p ≤ 0.001). NYHA Class ≥ III (OR 2.5; 95% CI 1.5, 4.2; p < 0.001) and age (OR 1.04; 95% CI 1.02, 1.07; p ≤ 0.001) proved to be additional predictive parameters. Hence, a modified RIVA Score (mRIVA) model was analyzed with a subset of established predictors (SHD, eGFR, epicardial puncture) as well as new predictive parameters (age, NYHA Class ≥ III), that achieved a higher predictive value for major complications compared with the model based on all RIVA variables. CONCLUSION: Adding age and functional heart failure status (NYHA class) as simple clinical parameters to the recently published RIVA Score increases the predictive value for ablation-associated complications in a large VT ablations registry.


Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Cardiopatias/etiologia , Fatores de Risco , Hospitais , Ablação por Cateter/métodos , Resultado do Tratamento
13.
Sleep Breath ; 27(5): 1753-1757, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36680625

RESUMO

PURPOSE: The present study validated a software-based electrocardiogram (ECG) analysis tool for detection of atrial fibrillation (AF) and risk for AF using polysomnography (PSG)-derived ECG recordings. METHODS: The Stroke Risk Analysis® (SRA®) software was applied to 3-channel ECG tracings from diagnostic PSG performed in enrolled subjects including a subgroup of subjects with previously documented AF. No subjects used positive airway pressure therapy. All ECG recordings were visually analyzed by a blinded cardiologist. RESULTS: Of subjects enrolled in the study, 93 had previously documented AF and 178 of 186 had an ECG that could be analyzed by either method. In subjects with known history of AF, automated analysis using SRA® classified 47 out of 87 ECG as either manifest AF or showing increased risk for paroxysmal AF (PAF) by SRA® (sensitivity 0.54, specificity 0.86). On visual analysis, 36/87 ECG showed manifest AF and 51/87 showed sinus rhythm. Among the latter subgroup, an increased risk for PAF was ascribed by SRA® in 11 cases (sensitivity 0.22, specificity 0.78) and by expert visual analysis in 5 cases (sensitivity 0.1, specificity 0.90). Among 36/178 ECG with manifest AF on visual analysis, 33 were correctly identified by the SRA® software (sensitivity and specificity 0.92). CONCLUSION: Sleep studies provide a valuable source of ECG recordings that can be easily subjected to software-based analysis in order to identify manifest AF and automatically assess the risk of PAF. For optimal evaluability of data, multiple channel ECG tracings are desirable. For assessment of PAF risk, the SRA® analysis probably excels visual analysis, but sensitivity of both methods is low, reflecting that repeated ECG recording remains essential.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Validação de Programas de Computador , Polissonografia , Eletrocardiografia/métodos , Software
14.
Pharmacology ; 107(11-12): 608-614, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36174497

RESUMO

INTRODUCTION: Hormone-mediated therapies are on the rise and are key therapies in the treatment of some of the most common cancer entities. Proarrhythmic effects have been described in patients treated with SERMs while little to none is known about the electrophysiological effects of the potentially less arrhythmogenic selective estrogen receptor degraders. METHODS: Twenty hearts of female New Zealand White rabbits were excised and retrogradely perfused employing a Langendorff setup. An electrophysiology study was performed to obtain CL-dependent action potential duration at 90% of repolarization (APD90), QT interval, effective refractory period (ERP), and post-repolarization refractoriness (PRR = ERP-APD90). After generating baseline data, the hearts were assigned to two groups and perfused with (n = 10) increasing doses of fulvestrant (1 µM and 5 µM; n = 10) or tamoxifen (2.5 µM and 7.5 µM; n = 10), and the protocol was repeated again. RESULTS: Fulvestrant led to a decrease in APD90 and QT interval and an increased PRR. The inducibility of ventricular tachycardia (VT) episodes was unaltered. Tamoxifen showed similar effects, resulting in a shortened APD90 and QT interval and no increased VT incidence in the setting of a prolonged PRR. CONCLUSION: The present study shows no acute proarrhythmic effect of tamoxifen and fulvestrant in an established whole heart model when employing clinically relevant concentrations.


Assuntos
Antiarrítmicos , Arritmias Cardíacas , Coelhos , Feminino , Animais , Antiarrítmicos/farmacologia , Fulvestranto/farmacologia , Fulvestranto/uso terapêutico , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/tratamento farmacológico , Coração , Potenciais de Ação , Tamoxifeno/farmacologia , Tamoxifeno/uso terapêutico
15.
Herzschrittmacherther Elektrophysiol ; 33(3): 290-296, 2022 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-35970909

RESUMO

Catheter-based ablation is nowadays a safe and widespread procedure for the treatment of cardiac arrhythmia. This requires exact anatomical knowledge both before and during the examination and is an important prerequisite for targeted treatment. At the beginning of the era of interventional catheter-based treatment, fluoroscopy was the only and usual means of visualization, whereas in the middle of the 1990s continuous 3D-mapping systems were developed for the non-fluoroscopic examination of patients. The correct use of these 3­D systems, which non-fluoroscopically visualize the catheter and mostly identify mechanisms of arrhythmia in great detail, nowadays makes an important contribution to successful interventional catheter treatment of arrhythmia; however, it is not uncommon for patients with ventricular arrhythmia to also carry implanted electronic devices, such as pacemakers, defibrillators or less frequently left ventricular hemodynamic support systems. All implantable devices lead to electromagnetic interferences, which can complicate the diagnostics and treatment during electrophysiological examinations and ablation. This article addresses the adversities and experiences associated with magnet-based 3D systems and implantable electromagnetically active cardiac devices.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Fenômenos Eletromagnéticos , Humanos
16.
J Pers Med ; 12(8)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-36013189

RESUMO

Background: Decision-making in primary prevention is not always trivial and many clinical scenarios are not reflected in current guidelines. To help evaluate a patient's individual risk, a new score to predict the benefit of an implantable defibrillator (ICD) for primary prevention, the MADIT-ICD benefit score, has recently been proposed. The score tries to predict occurrence of ventricular arrhythmias and non-arrhythmic death based on data from four previous MADIT trials. We aimed at examining its usefulness in a large single-center register of S-ICD patients with various underlying cardiomyopathies. Methods and results: All S-ICD patients with a primary preventive indication for ICD implantation from our large single-center database were included in the analysis (n = 173). During a follow-up of 1227 ± 978 days, 27 patients developed sustained ventricular arrhythmias, while 6 patients died for non-arrhythmic reasons. There was a significant correlation for patients with ischemic cardiomyopathy (ICM) (n = 29, p = 0.04) to the occurrence of ventricular arrhythmia. However, the occurrence of ventricular arrhythmias could not sufficiently be predicted by the MADIT-ICD VT/VF score (p = 0.3) in patients with (n = 142, p = 0.19) as well as patients without structural heart disease (n = 31, p = 0.88) and patients with LV-EF < 35%. Of the risk factors included in the risk score calculation, only non-sustained ventricular tachycardias were significantly associated with sustained ventricular arrhythmias (p = 0.02). Of note, non-arrhythmic death could effectively be predicted by the proposed non-arrhythmic mortality score as part of the benefit score (p = 0.001, r = 0.3) also mainly driven by ICM patients. Age, diabetes mellitus, and a BMI < 23 kg/m2 were key predictors of non-arrhythmic death implemented in the score. Conclusion: The MADIT-ICD benefit score adds a new option to evaluate expected benefit of ICD implantation for primary prevention. In a large S-ICD cohort of primary prevention, the value of the score was limited to patients with ischemic cardiomyopathy. Future research should evaluate the performance of the score in different subgroups and compare it to other risk scores to assess its value for daily clinical practice.

17.
J Cardiovasc Dev Dis ; 9(8)2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-36005421

RESUMO

The implantation of cardiac devices significantly reduces morbidity and mortality in patients with cardiac arrhythmias. Arrhythmias as well as therapy delivered by the device may impact quality of life of patients concerned considerably. Therefore we aimed at conducting a systematic search and meta-analysis of trials examining the impact of the implantation of cardiac devices, namely implantable cardioverter-defibrillators (ICD), pacemakers and left-ventricular assist devices (LVAD) on quality of life. After pre-registering the trial with the PROSPERO database, we searched Medline, PsycINFO, Web of Science and the Cochrane databases for relevant publications. Study quality was assessed by two independent reviewers using standardized protocols. A total of 37 trials met our inclusion criteria. Of these, 31 trials were cohort trials while 6 trials used a randomized controlled design. We found large pre-post effect sizes for positive associations between quality of life and all types of devices. The effect sizes for LVAD, pacemaker and ICD patients were g = 1.64, g = 1.32 and g = 0.64, respectively. There was a lack of trials examining the effect of implantation on quality of life relative to control conditions. Trials assessing quality of life in patients with cardiac devices are still scarce. Yet, the existing data suggest beneficial effects of cardiac devices on quality of life. We recommend that clinical trials on cardiac devices routinely assess quality of life or other parameters of psychological well-being as a decisive study endpoint. Furthermore, improvements in psychological well-being should influence decisions about implantations of cardiac devices and be part of patient education and may impact shared decision-making.

18.
J Cardiovasc Dev Dis ; 9(8)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36005439

RESUMO

1. Introduction: Pulmonary vein isolation (PVI) is an established procedure used to achieve rhythm control in atrial fibrillation (AF). In obese patients (pts), in whom AF occurs more frequently, a reduced effectiveness of PVI has been observed. Therefore, this study's aim was to compare the long-term efficacy of PVI between obese and non-obese patients. 2. Methods: We enrolled 111 consecutive pts with a body mass index (BMI) of >30 kg/m2 undergoing PVI from our large registry. Procedural data and outcomes were compared with a matched group of 115 non-obese PVI pts and the long-term outcomes were analyzed. 3. Results: Overall follow-up duration was 314 patient-years in the obese and 378 patient-years in the non-obese group. The follow-up rate was 71% in the obese and 76% in the non-obese group. In both groups, their AF-characteristics did not differ significantly, while known risk factors were significantly more prevalent in the obese group. Procedural characteristics were similar in both groups. During follow-up, the obese pts demonstrated significant weight loss compared to the non-obese pts, while at the same time, the overall recurrence rate during follow-up did not differ significantly between both groups (obese: 39.2% and non-obese: 43.7%). PVI related and long-term complications were comparable between both groups. In the univariate analysis, obesity was not found to be associated with an increased AF recurrence risk. 4. Conclusion: These real-life data demonstrate that obese pts may not show higher AF recurrence rates after PVI compared to pts with normal body weight. Furthermore, PVI was found to be safe and effective in obese patients; thus, a BMI alone may not be a criterion for refusal of PVI.

19.
J Pers Med ; 12(8)2022 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-35893313

RESUMO

Syncopes are a very common phenomenon and have a high recurrence rate. The differentiation between the psychogenic and physical, especially of arrhythmic origin, remains difficult. In many cases, an implantable loop recorder is used for the detection of possible arrhythmias, leading to syncopes. Yet, the existing literature suggests that psychological factors may play a significant role in recurrent syncopes. We aimed at analyzing the potential role of several psychological factors on the recurrence of arrhythmic or non-arrhythmic syncopes. Methods and results: A total of 119 patients, who had received an implantable loop recorder for recurrent syncopes at our center between 01/2018 and 12/2021, participated in this retrospective cohort study. Anxiety, depression and quality of life were assessed using extensively validated questionnaires (GAD-7, PHQ-9 and SF-12). The mean follow-up after loop recorder implantation was 710 ± 430 days and 50% of patients were female. The mean patient age was 54.8 ± 18.6 years. Most patients had no evidence of structural heart disease (84%), and normal LV function (92%). A statistical analysis revealed that the presence of structural heart disease was the strongest predictor for arrhythmic syncope during follow-up. In patients with non-arrhythmic syncopes, we found significantly higher levels of anxiety (GAD-7 score: 2.5 ± 2.6 vs. 4.8 ± 4.3) and depression (PHQ-9 score: 3.9 ± 3.6 vs. 6.8 ± 5.1), and a lower quality of life (SF-12 score: 33.7 ± 6.4 vs. 29.6 ± 7.8). Discussion: We identified factors as contributors to a better identification of patients at risk for arrhythmic as well as non-arrhythmic syncopes. Especially anxious or depressive symptoms may hinted at non-arrhythmic causes of syncope. However, the study was limited by its retrospective design and low patient number. Further trials should likewise combine the diagnostic yield of loop recorders with psychometric evaluations before implantation and combine it with additional diagnostic measures, such as video monitoring, to further examine the role of psychological factors in the pathomechanism and treatment of syncope.

20.
Herzschrittmacherther Elektrophysiol ; 33(2): 161-174, 2022 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-35556156

RESUMO

As with all cardiac interventions, performing left ventricular ablation requires profound knowledge of cardiac anatomy. The aim of this article is to provide an overview of left ventricular anatomy and to characterize complex and clinically relevant structures from an electrophysiologist-centered perspective. In addition to the different access routes, the trabecular network, the left ventricular outflow tract, and the left ventricular conduction system, complex anatomical structures such as the aortomitral continuity and the left ventricular summit are also explained. In addition, this article offers multiple clinical examples that combine ECG, anatomy, and electrophysiologic study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...